New Launching 220kw 16000rpm High Speed Permanent Magnetic Motor

New Launching 220KW 16000RPM Large Pace Long term Magnetic Motor

Product Attribute
one.Appropriate for the 16000rpm high velocity
two.High power & large torque
3.Large efficiency
4.Modest measurement
five.Low sound minimal vibration
6.Patented cooling structure
7.Straightforward servicing and lengthy existence time
eight.Tough, reputable

Specifications
Design variety: SRPM205H4O220
Voltage: 380V AC
Rated Energy: 220KW
Working velocity: 16000rpm
Effectiveness: ≥95.5%
Isolation: H
Drinking water/dust Proof: IP54
Pole Amount: four
Cooling Method: Oil

Application
High-velocity Compressors,Enthusiasts,Pumps

Other motors you will be fascinated in

Motor kind Voltage
(V AC)
Rated energy
(kW)
Rated torque (N.m) Rated pace
(rpm)
Efficiency
(%)
Services Issue Insulation Ingress safety Pole Quantity Bodyweight
(kg)
Cooling Strategy Position Sign Set up Technique
SRPM151M8XW11 380 11 11 9600 ninety six S1 H/F IP67 eight 10 Oil circulation Resolver B35
SRPM205M8XO45 380 forty five 36 12000 ninety six.3 S1 H/F IP67 eight 35 Oil circulation Resolver B35
SRPM205M8XO55 380 55 forty three.8 12000 ninety six.3 S1 H/F IP67 8 38 Oil circulation Resolver B35
SRPM205M8XO75 380 75 fifty nine.7 12000 ninety six.five S1 H/F IP67 8 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 seventy one.6 12000 ninety six.5 S1 H/F IP67 8 forty seven Oil circulation Resolver B35
SRPM205M8XO110 380 one hundred ten 87.six 12000 96.five S1 H/F IP67 eight seventy five Oil circulation Resolver B35
SRPM205M8XO132 380 132 one zero five 12000 96.5 S1 H/F IP67 8 eighty Oil circulation Resolver B35
SRPM205M8XO160 380 160 127.3 12000 96.5 S1 H/F IP67 eight 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 ninety six.5 S1 H/F IP67 eight 95 Oil circulation Resolver B35

FAQ
one. Can performanent magnet synchronous motor be utilized as generator? 

No. Permanent magnet synchronous motor is definitely diverse from generator. It is only ac motor that outputs pace and torque to generate electric powered units, but not power offer. 
 
2. Why can not straight use 3 stage ac offer voltage to start long term magnet synchronous motor? 
Becuase rotor is with huge innertia, and magetic documents spins so rapidly that static rotor has no way to spin with magetic submitted. 
 
3. Any specific technological ask for on this motor's VFD driver? And Do you have these kinds of driver? 
Long term magnet synchronous motor's driver should be vector control VFD with unique internal computer software, these kinds of as Siemens 6SE70 sequence, Yakawa CR5 collection, ABB ACS800 sequence, Mitsubishi A740 sequence, B&R P84 and P74 sequence, and so forth.. Indeed, our MH300 sequence VFD matches with this motor. 
 
four. Is there any protective actions to protect long lasting magnet rotor from failure? 
Yes, every single long lasting magnet rotor passes corrossion resistance, consistency, substantial temperature demagnetization take a look at, linear demagnetization test, and many others. Its demagnetization index is inside of 2%. But if operating surroundings is severe oxiditive corrosion, kindly advise for increased defense stage. 
 
five. Where is this long term magnet synchronous motor normally utilized to? 
This permanent magnet synchronous motor is generally utilised to variable frequency speed situation.

 

New Launching 220kw 16000rpm High Speed Permanent Magnetic Motor